Technical data sheet
Zinc anode, high temperature, HT-Anode
The special HT-anode is designed for use in tanks intended for the carriage of liquid cargo at elevated temperatures.
Properties
The HT-anode alloy is composed with the objective of obtaining consistent behaviour at ambient temperatures up to 90 °C, were conventional anodes tend to collapse. The HT-anode is tested in accordance with the 20 °C criteria of DNV-RP-B401.
Capacity
The high temperature zinc anode capacities have been verified by a 28 day test performed by Force Technologies adapted from the procedures in DNV-RP-B401, annex B and C.
You may also visit the webshop
Performance at elevated temperatures
Temperature | Capacity | Potential | Electrode | Method |
---|---|---|---|---|
20 °C | 800 Ah/kg | -1 030 mV | Ag/AgCl | Closed circuit |
60 °C | 769 Ah/kg | -1 010 mV | Ag/AgCl | Closed circuit |
80 °C | 774 Ah/kg | -980 mV | Ag/AgCl | Closed circuit |
90 °C | 754 Ah/kg | -950 mV | Ag/AgCl | Closed circuit |